V7 — LEFT OUTBOARD CARRIER + INDEPENDENT MICROSCOPE CARRIAGE
FIT TEST, NOT PHYSICALLY VERIFIED. Use this version, not v5's right-side tray.

WHAT CHANGED
• Servo and Nano tray are LEFT (-X), away from the printer head.
• Attachment rail/rectangular loop are RIGHT (+X), toward the head.
• The microscope clamp is now a SEPARATE carriage on two broad supported feet.
  Two M3 locks, 48mm apart, slide in parallel slots: 12mm total X travel.
  ONLY microscope/clamp/dial move. Carrier, servo, Nano and head loop stay fixed.
  Thus microscope-to-wheel distance genuinely changes, rather than moving both.
• X is normal to an ASSUMED YZ head attachment face. We use “front/back” to
  mean stand-off normal to that face. Front preview looks from -Y, Top down Z;
  +X appears RIGHT in both. Actual printer-face orientation remains unmeasured.
• Servo platform raised from assembly Z10 to Z24 to clear the moving clamp.
  Original loop-free drop slide mounts rotated 180deg about Z, not mirrored.
• Original loop retained: 25 x16.4 outer, 23.6 x13 opening, physical thickness
  6mm versus original3mm. Short fused root joins the fixed rail. This loop is
  flat in base.stl, so its 6mm thickness is also actual print-Z thickness.

THE SCREW TABS
The two optional external M3 Nano mounting ears were for separately screwing
that earlier tray to another surface. They are unnecessary once the tray is
fused to its carrier, so they remain removed. Do NOT remove the barrel-clamp
bolt ears, the two servo slide foot mounts, four cradle mounts, or new two
microscope carriage locks. USB strain-relief/retention slots are functional,
not redundant mounting tabs.

PRINT / REUSE
NEW: base.stl x1 and microscope_clamp.stl x1. Replace the old combined base.
REUSE unchanged from v3-small-wheel: slide.stl x1 (LOOP FREE), cradle.stl x1,
wheel.stl x1 and spacer.stl x4. These STLs are byte-identical to v3.
The loop-bearing v4 slide must NOT be used. The v5 loop-free slide is reusable.
The v1/v2 larger wheel is not the selected wheel; do not substitute silently.
cradle_ears.stl, wheel_blank.stl and sleeve_wheel.stl are alternatives, not
additional parts. clamp_coupon.stl is a clearance coupon, not a carriage.
Default assembly: six geometry groups, nine printed pieces. all_print.stl is
an optional separated 9-piece plate; check bed/brim margins in your slicer.

Export orientations are ready for the bed. Base and moving clamp are flat;
the long drop slide is ON ITS SIDE. Do not mistake that orientation for the
assembly orientation. Slide uses inverse print transform Rx(-90deg), followed
by Rz(180deg), with its foot underside at assembly Z24. Base export is lifted
6mm for printing; assembly/viewer undo that 6mm. Cradle also uses the original
inverse print transform followed by Rz(180deg). Viewer embeds these exact
transformed meshes, not a rebuilt approximation.

Suggested starting print: 0.20mm layers, 4-5 walls, 40-50% infill. Inspect
slicer bridges and use removable supports under the raised servo platform /
crossbeam. This NEW carrier is NOT promised support-free. Clear slots and
M3 holes after printing; don't force hardware through an undersized hole.
Use a material suitable for the REAL printer-head temperature. PLA is for
cold fit checks, not an unverified hot-head structural mount. Check layer
adhesion, support removal and clamp flex before loading the microscope.

ASSEMBLY / ADJUSTMENT
1. Fit-test the 33.3mm clamp bore on the measured32.7mm barrel. Keep the4mm
   wall, 10mm band, 0.8mm slit and retained M3 clamp bolt/nut. Tighten gently.
2. Place gold microscope_clamp feet directly onto the two fixed carrier rails.
   Add TWO NEW M3x18-20 bolts with flat washers and nuts through the feet and
   X slots. Stack is approximately11mm before washers/nut. Verify bolt length
   and underside clearance. Both bolts must be locked before operation.
3. Mount reused drop slide on the raised left platform with its two existing
   M3 foot bolts. Mount servo saddle using four existing bolts and four2.5mm
   spacers. Recheck bolt lengths after any washer changes. No spring assumed.
4. Strap servo securely to its open saddle. 27.8mm measured ear pitch is offered
   in cradle_ears alternative; actual ear/horn layout is unverified. 12.1mm was
   measured thickness. “30.5 from wires to spinning thing” is NOT a shaft datum.
5. Attach wheel to EXISTING horn with at least two balanced suitable screws.
   Do not print/guess a servo spline. Centre clearance7.2mm, shallow9mm relief;
   nominal M2 slots at radius5.8-6.2mm are NOT guaranteed to match your horn.
   If unmatched, use wheel_blank and drill to the actual horn safely OFF servo.
6. Fit real rubber / O-ring or sleeve. Do not expect bare PLA reliable grip.
   Small core OD20, groove root17.6, height9. A2mm-section O-ring would imply
   about21.6mm rolling OD; actual tire, seating, stretch and compression unknown.
   Prior larger core24/root21.6 implied25.6mm rolling OD with same assumption.
   Ideal ratio21.6/25.6=0.844 speed (~16% slower); inverse1.185 tangential force
   (~19% higher), ignoring losses. Smaller wheel does NOT guarantee less slip.
7. With power OFF, loosen both carriage locks and slide ONLY microscope toward
   or away from wheel; retighten both. Slot centre range X=-2.7..9.3. Default
   assembly microscope X=-2.5, servo parameter20.14, cradle parameter-38.
   Existing servo radial adjustment is retained: tested servo parameter20..39
   (wheel moves LEFT as parameter increases). Test height window-42..-32;
   these height coordinates are measured from the MODEL datum, not your scope.
   Do not use untested overtravel merely because the old vertical slots allow it.
   Align tire with the ACTUAL exposed silver dial below the clamp, never body.
   Use light contact, then lock all screws; back away to disengage as needed.
8. Hold microscope securely; manually check full focus travel and servo limits
   before power. Set safe servo endpoints. Do not use this mount as fall restraint.

DIMENSIONS / UNKNOWN FIT
Nano pocket stays63.2 x38.8 CAD; calibration intention was about63.7 printed
length, not a promise or automatic scale factor. USB local-Y shift remains
-11.7mm; left USB exit, lip/end walls, switch access and tie slots preserved.
Tray entirely X=-70.4..-2.8. Head loop frame X=24.6..49.6, Y=19.8..36.2;
root joins fixed rail. These coordinates explain placement, NOT fan clearance.
The microscope's22mm measurement was a CHORD, not an exact dial diameter.
19.8mm exposed axial width and exact dial-to-clamp datum remain uncertain.
Grey dial uses schematic radius11.2 only. Grey body/servo/horn and rubber are
reference-only, not reverse-engineered physical geometry. Actual shaft offset,
head/fan, cables, screw heads, clamp jaws, flex, tire preload and load capacity
need a real fit check. Overall microscope length106.4 is known; grey cylinders
are illustrative segments, NOT a dimensionally complete scope model.
At default, schematic dial-to-wheel axes are22.0mm apart. Sliding microscope
alone to +9.3 increases this to33.67mm. This confirms genuine relative motion,
not guaranteed tire contact with your exact hidden/internal dial.

VIEWER / PREVIEWS / VALIDATION
Open microscope-assembly-v7-left-carriage.html directly in Chrome. Self-contained,
no internet/server/file picker; official Three.js r181 + OrbitControls inline,
MIT licence included. Drag rotate, wheel zoom, right-drag pan; touch pinch and
2-finger pan. Front/Top establish handedness. Microscope slider demonstrates
the actual separate carriage. Exploded view is only a display aid.
front_top_layout_v7.png labels LEFT/RIGHT and assumed normal direction.
assembly_preview_v7.png and carriage_loop_detail_v7.png use actual STL meshes.
SCAD source: independent_microscope_carriage_v7.scad, default part="assembly".
Set part to any individual STL stem, or all_print. Source assembly and printable
parts compile without undefined-name warnings/errors. Individual STLs each
one connected watertight positive-volume solid; all_print nine components.
720 printed-mesh pair checks across48 sampled microscope/servo/height combinations
passed, plus known-barrel and SCHEMATIC dial/case checks. Sampling is not a proof
of every continuous pose or real-world fit. See validation.json and VALIDATION.txt.
HTML embedding hashes, bounds/indices, JavaScript syntax, independent slider
motion, fixed other groups, exploded composition and front/top handedness pass
static/math tests. NO browser runtime test performed here; parent visual review
is pending. No claimed browser console result or physical microscope fit.